Track geometry measurement - TQM accuracy
|
|
|
|
In order to have a broader picture of possible and attainable accuracy of TQM track geometry readings a typical track geometry measurement accuracy expectancy goal needs to be set. Track geometry measurement accuracy goal: As TQM aims to replace laborious hand versine measurements, the accuracy of Generated Versine (derived from recorder measurements) must match a hand versine measurement accuracy of +/-2mm. Table A indicate (projection scale derived) expected track geometry singular measurement accuracy related to different chord lengths SB (short bases).
|
|
+/-2mm
|
+/-2mm
|
HV Accuracy Goal for 10 and 20m chord
|
+/-2mm
|
+/-2mm
|
|
10m
|
20m
|
10m
|
20m
|
10m
|
20m
|
10m
|
20m
|
|
1m
|
1m
|
2m
|
2m
|
Length of Measuring Base
|
3m
|
3m
|
4m
|
4m
|
|
100
|
400
|
25
|
100
|
Projection Scale
|
11
|
44
|
6
|
25
|
|
+/- 0.02 mm
|
+/- 0.005 mm
|
+/- 0.08 mm
|
+/- 0.02 mm
|
Required Accuracy of a TQM Singular Measurement
|
+/- 0.18 mm
|
+/- 0.05 mm
|
+/- 0.32 mm
|
+/- 0.08 mm
|
|
|
|
|
|
|
|
|
|
|
|
System Precision
|
System Calibration
|
System Corrections
|
|
Design
|
Engineering
|
Ref. Blocks
|
Temp.Control
|
Design
|
Correction
|
|
Table A. Track geometry - expected accuracy of TQM typical measurement
|
|
|
|
|
|
|
|
[mm]
|
Curve Radius [in metres]
|
|
Compiled measurement accuracy on curve of 1000m radius
|
|
HV
|
1m SB
|
2m SB
|
3m SB
|
4m SB
|
|
Short base
|
Horiz. Versine magnitude
|
Single measur. accuracy
|
Gen. Versine on 20m chordG
|
|
2.0
|
62
|
250
|
562
|
1000
|
|
|
1.0
|
125
|
500
|
1125
|
2000
|
|
1m
|
0.12 mm
|
+/- 0.005 mm
|
50 +/- 2mm
|
|
0.5
|
250
|
1000
|
2250
|
4000
|
|
2m
|
0.50 mm
|
+/- 0.02 mm
|
50 +/- 2mm
|
|
0.2
|
625
|
2500
|
5625
|
10000
|
|
3m
|
1.12 mm
|
+/- 0.05 mm
|
50 +/- 2mm
|
|
0.1
|
1250
|
5000
|
11250
|
20000
|
|
4m
|
2.00 mm
|
+/- 0.08 mm
|
50 +/- 2mm
|
|
Table B. Versines and Radius
|
|
Table C. SB measurements on 1000m radius
|
|
|
|
|