navBar

TQM - Track geometry measuring recorder

 

 

Screen arrangement:
PC touch Sensitive Screen is divided into two areas: dark grey Vertical Bar VB area and light grey Recording Window (RW) area

Vertical Bar (VB)
VCB area contains the following features:
 - File Input (File Name , Chainage, Direction)    
 - Buttons (Recording, Exit, Chainage Reset)      
 - Display windows (File Name, Sensor, Control Diodes,   Distance, Recording Speed)

Track geometry recording window (RW)
RW area contains the following:
 - Recording window (central position)
 - Channel display selection buttons (Light grey        buttons located directly above recording window)   - Graphs display configuration buttons (controls graph   Vertical and Horizontal Scale plus Exceedences )
 - Events Coding buttons (blue color) with string       coding (top row) and point coding (bottom row)

Recording Display option:
 - Tabular Form (spreadsheet format)
 - All Graphs (all channels in one window)
 - Selective channel (seven options)

Track geometry recorded file format: TQM records data at 100mm interval (additionally VB displays measured distance in mm resolution). Recorded file format of track geometry data is shown
Recording speed - 5km/hr approx.
 

Track geometry recording - digital format

TQM track geometry recording - one channel screen display

TQM track geometry recorded file format